Skip to page content

Major hazard assurance

Critical Control Centre

Govern safety-critical elements, TARP escalation and statutory assurance without replacing approved site controls.

How the site filter works

Your site choice is remembered across workspace views.

Critical elements use explicit site assignments or linked value-chain nodes; instrumented functions use explicit assignments. TARPs follow their subject links. Compliance follows equipment and asset-type applicability, not a claim of site-specific verification.

All locations: 12 of 12 critical elements. 0 have no resolvable site and remain under All locations; edit them there to assign a site. A lack of matching records is not evidence of safety or compliance.

Safety-critical elements

12

Impaired or overdue

3

Escalated TARPs

1

Compliance exceptions

5

detective

Dragline boom structural monitoring

DL-01

overdue

Hazard: Structural failure of the dragline boom

Standard: Strain alarms acted on within one shift; NDT indications dispositioned before next operation

Last verified: 2026-10-17

Next verification: 2026-10-24

Owner: Dragline Superintendent

detective

Conveyor belt rip detection (CV-02)

CV-02 Overland

failed

Hazard: Belt rip causing fire and long outage

Standard: Rip loops tested weekly; trip within 3 s of loop break

Last verified: 2026-10-24

Next verification: 2026-10-31

Owner: Fixed Plant Superintendent

preventive

Conveyor pull-wire emergency stops

CV-01–CV-04

effective

Hazard: Entanglement in conveyors

Standard: Every pull-wire trips the drive within 1 s; tested monthly

Last verified: 2026-10-14

Next verification: 2026-11-13

Owner: Fixed Plant Superintendent

detective

Highwall prism monitoring

Highwall Strip 14

effective

Hazard: Ground failure (highwall)

Standard: Prism read every hour; TARP L1 at 5 mm/day

Last verified: 2026-10-26

Next verification: 2026-10-27

Owner: Geotechnical Engineer

detective

Spoil dump stability inspection

Dragline spoil

effective

Hazard: Ground failure (spoil)

Standard: Inspected each shift by the dragline supervisor; cracks reported

Last verified: 2026-10-25

Next verification: 2026-10-26

Owner: Dragline Supervisor

detective

Stockpile thermal monitoring

Product Stockpile P3

degraded

Hazard: Spontaneous combustion

Standard: Thermal scan daily; TARP L2 at 65 °C

Last verified: 2026-10-26

Next verification: 2026-10-27

Owner: CHPP Superintendent

preventive

Haul truck proximity detection

Haul fleet

effective

Hazard: Vehicle interaction

Standard: All trucks fitted and reporting; alarm tested pre-start

Last verified: 2026-10-23

Next verification: 2026-10-30

Owner: Mining Superintendent

mitigating

Mobile plant fire suppression

Haul, dig and support fleet

effective

Hazard: Fire on mobile plant

Standard: Systems serviced 6-monthly to AS 5062; actuation tested

Last verified: 2026-06-01

Next verification: 2026-11-30

Owner: Maintenance Superintendent

preventive

HV isolation and earthing (dragline)

DL-01 trailing cable

verification due

Hazard: Electric shock and arc flash

Standard: Isolation verified by test-before-touch; earth leakage protection tested monthly

Last verified: 2026-09-23

Next verification: 2026-10-23

Owner: Electrical Engineer

preventive

Windrows on haul roads and dumps

Haul roads

effective

Hazard: Vehicle over edge

Standard: Windrow at least half wheel height of the largest vehicle

Last verified: 2026-10-21

Next verification: 2026-10-28

Owner: Mining Supervisor

detective

Mine Water Dam wall inspection

MWD-1

effective

Hazard: Dam failure

Standard: Weekly inspection; piezometers read monthly

Last verified: 2026-10-22

Next verification: 2026-10-29

Owner: Environment Superintendent

mitigating

CHPP fire deluge

CHPP

verification due

Hazard: Fire in the CHPP

Standard: Deluge operates on detection; flow test 6-monthly

Last verified: 2026-05-16

Next verification: 2026-11-14

Owner: CHPP Superintendent