Pressure systems & pipelines

Integrity Assurance

Risk-based inspection register: wall thickness, corrosion rate, remaining life and next statutory inspection for vessels, piping, pipelines and tanks. Calculations are advisory — the site inspection standard and engineer of record govern.

How the site filter works

Your site choice is remembered across workspace views.

Systems and summary counts match the recorded location name. Unassigned systems remain under All locations; up to 300 systems are loaded. Governing inspection limits and assessment formulas are unchanged.

Registered systems

6

Critical integrity findings

0

Inspections overdue

1

Remaining life not assessable

0

AR-3

MIA workshop air receiver AR-3

Bengalla Mine (Hunter Valley) · Compressed air · AS 1210

high · 60
Measured thickness
8.40 mm
Retirement thickness
7.60 mm
Corrosion rate
0.336 mm/yr
Remaining life
2.4 yr
Next inspection
2026-02-03
Operating / design
800 / 1050 kPa

Rate basis: measured two point · Interval rule: min(½ remaining life, code maximum 4 yr) — site standard and engineer of record take precedence.

  • Remaining life 2.4 years — plan replacement or repair scope now.
  • Thickness inspection due 2026-02-03 is overdue.
  • Relief device PSV-AR3 test overdue since 2026-10-02.

DEMO — generated demonstration record for Bengalla. Replace with site-system data.

FW-200

CHPP fire water ring main

Bengalla Mine (Hunter Valley) · Coal Handling & Preparation Plant (CHPP) · Fire water · AS 2419.1

high · 56
Measured thickness
6.10 mm
Retirement thickness
5.50 mm
Corrosion rate
0.244 mm/yr
Remaining life
2.5 yr
Next inspection
2027-05-15
Operating / design
1100 / 1600 kPa

Rate basis: measured two point · Interval rule: min(½ remaining life, code maximum 5 yr) — site standard and engineer of record take precedence.

  • Remaining life 2.5 years — plan replacement or repair scope now.
  • Relief device PRV-FW1 test overdue since 2026-09-02.

DEMO — generated demonstration record for Bengalla. Replace with site-system data.

FP-100

Fuel farm transfer piping

Bengalla Mine (Hunter Valley) · Diesel · AS 4041

high · 28
Measured thickness
5.40 mm
Retirement thickness
4.80 mm
Corrosion rate
0.254 mm/yr
Remaining life
2.4 yr
Next inspection
2026-12-18
Operating / design
450 / 1000 kPa

Rate basis: measured two point · Interval rule: min(½ remaining life, code maximum 5 yr) — site standard and engineer of record take precedence.

  • Remaining life 2.4 years — plan replacement or repair scope now.

DEMO — generated demonstration record for Bengalla. Replace with site-system data.

AR-1

CHPP plant air receiver AR-1

Bengalla Mine (Hunter Valley) · Coal Handling & Preparation Plant (CHPP) · Compressed air · AS 1210

low · 0
Measured thickness
10.60 mm
Retirement thickness
9.20 mm
Corrosion rate
0.200 mm/yr
Remaining life
7.0 yr
Next inspection
2029-03-12
Operating / design
750 / 1050 kPa

Rate basis: measured two point · Interval rule: min(½ remaining life, code maximum 4 yr) — site standard and engineer of record take precedence.

DEMO — generated demonstration record for Bengalla. Replace with site-system data.

DL-AR-1

Dragline DL-01 brake air system receiver

Bengalla Mine (Hunter Valley) · Prestrip & dragline overburden · Compressed air (brakes) · AS 1210

low · 0
Measured thickness
12.10 mm
Retirement thickness
10.80 mm
Corrosion rate
0.250 mm/yr
Remaining life
5.2 yr
Next inspection
2028-04-09
Operating / design
830 / 1000 kPa

Rate basis: measured two point · Interval rule: min(½ remaining life, code maximum 2 yr) — site standard and engineer of record take precedence.

DEMO — generated demonstration record for Bengalla. Replace with site-system data.

FT-1

Fuel farm bulk diesel tank FT-1 (2 ML)

Bengalla Mine (Hunter Valley) · Diesel · API 653 / AS 1940

low · 0
Measured thickness
7.10 mm
Retirement thickness
6.00 mm
Corrosion rate
0.166 mm/yr
Remaining life
6.6 yr
Next inspection
2028-10-06
Operating / design
— / —

Rate basis: measured two point · Interval rule: min(½ remaining life, code maximum 5 yr) — site standard and engineer of record take precedence.

DEMO — generated demonstration record for Bengalla. Replace with site-system data.