Scan Analysis

Upload 3D scans, overlay your asset register, and let AI detect condition anomalies that improve over time.

Review SLA Breach

0 overdue

Oldest critical is 0 day(s) old.

critical
0 / SLA 1d
major
0 / SLA 3d
moderate
0 / SLA 7d
minor
0 / SLA 14d
Clean workflow
Active scan: Bengalla CHPP & conveying thermal survey (DEMO)

3D scan → Excel match → verified report

Follow these steps in order: use the existing walkthrough, add or capture evidence frames, match the spreadsheet, then verify the outputs.

01

Use the loaded walkthrough

Start from the existing South West Sports Centre Matterport walkthrough.

02

Capture scan evidence

Add photos or scan frames so AI has visual evidence to inspect.

03

Match the spreadsheet

Import the Excel/CSV findings and match rows to the scan evidence.

04

Review and approve

Verify AI findings, correct issues, then export the condition report.

Frames: 0
Findings: 8
Pending review: 8

Scans (1)

Uploaded
Frames (0)
AI analyzed (8)
Certified

Bengalla CHPP & conveying thermal survey (DEMO)

SCAN_DATASET • 5 assets overlaid • 8 anomalies detected

No 3D model available for this scan

Confirm with Inspector Spreadsheet

Upload the condition spreadsheet for this scan. We match each row to the AI findings and show what's confirmed, AI-only, and sheet-only.

No spreadsheet uploaded yet.

Condition Over Time

No previous scans of this location to compare

Analyzed Image

Heatmap
Scan preview
wear

Condition AI Model

Continuously learning from your feedback

Model Versionv1.0 (baseline)
Accuracy70.0%
Trained on
0 samples
FP rate
0.0%
Pending training samples
0

Model performance

Once human reviewers verify, correct, or reject a few AI findings, precision metrics will show up here per model version.

Verify Condition Reports

8
Review each highlighted asset photo, then click Verify, Fix AI, or Not issue. Or Log finding for defects you spot yourself.
8
Pending
0
Approved
0
Corrected
0
Rejected

Smart Auto-Approve

Only review uncertain cases — let AI handle the obvious ones

8 pending
95+%
0
90-95%
2
80-90%
3
70-80%
1
<70%
2
Threshold: ≥90%2 eligible
Smart Triage
8 pending
Critical • AI confident
4

Approve & auto-draft urgent work orders in one click.

Critical • AI unsure
1

High stakes, low confidence — human review required.

Minor • AI unsure
3

Lowest priority — review in keyboard mode when you have time.

Critical bucket auto-drafts work orders. All actions logged with your name.

2 high-confidence findings (≥90%) ready for bulk verify
Anomaly
AI detected: wear
AI 93%

Needs verification

Inspect the highlighted photo, then choose: verify, correct, or reject.

Action needed
wear
critical • score 5

on BEN CHPP Feed Conveyor

thermal-v2.3 (demo)

DEMO: carry idler at station 112 reads 84.5°C against 33°C on neighbouring idlers (ΔT 51°C). Pattern matches a seizing bearing. Idler seizure on a fire-risk coal conveyor can heat the belt; change out at the next stop and check the belt cover for heat damage.

A short note on rejection trains the model to avoid the same false positive.

Verification action
Anomaly
AI detected: wear
AI 86%

Needs verification

Inspect the highlighted photo, then choose: verify, correct, or reject.

Action needed
wear
major • score 4

on BEN CV-04 Reclaim to Loadout Drive

thermal-v2.3 (demo)

DEMO: gearbox high-speed bearing housing 76.7°C, about 22°C above the low-speed end. Agrees with the rising vibration trend on this drive. Take an oil sample and plan a bearing change before the next train-loading campaign.

A short note on rejection trains the model to avoid the same false positive.

Verification action
Anomaly
AI detected: wear
AI 81%

Needs verification

Inspect the highlighted photo, then choose: verify, correct, or reject.

Action needed
wear
major • score 4

on BEN CV-02 Overland Drive Motors (3 × 750 kW)

thermal-v2.3 (demo)

DEMO: drive 2 non-drive-end bearing at 83.4°C while drives 1 and 3 run at about 58°C. Check greasing and the bearing insulation (shaft currents are common on VSD-driven conveyor motors).

A short note on rejection trains the model to avoid the same false positive.

Verification action
Anomaly
AI detected: wear
AI 90%

Needs verification

Inspect the highlighted photo, then choose: verify, correct, or reject.

Action needed
wear
critical • score 5

on BEN CHPP Dense Medium Cyclone Pump

thermal-v2.3 (demo)

DEMO: bearing housing at 89.2°C. This is the lowest-health asset on site (41). A DMC pump trip stops the dense-medium circuit and the whole CHPP feed. Bring the scheduled rebuild forward.

A short note on rejection trains the model to avoid the same false positive.

Verification action
Anomaly
AI detected: other
AI 74%

Needs verification

Inspect the highlighted photo, then choose: verify, correct, or reject.

Action needed
other
moderate • score 3

on BEN Dragline Trailing-Cable Substation DS-01

thermal-v2.3 (demo)

DEMO: warm section on the middle phase at the coupler, 68.5°C (about 12°C above the other phases). Likely a high-resistance joint. Re-terminate at the next dragline walk; an unplanned cable fault stops the dragline.

A short note on rejection trains the model to avoid the same false positive.

Verification action
Anomaly
AI detected: other
AI 88%

Needs verification

Inspect the highlighted photo, then choose: verify, correct, or reject.

Action needed
other
major • score 4

on BEN CHPP Motor Control Centre MCC-1

thermal-v2.3 (demo)

DEMO: tier 2 bus joint at 79.7°C against 31°C on matching joints (ΔT 49°C, above the NETA 'repair immediately' band of more than 15°C over similar components). Torque-check under isolation. Arc-flash PPE applies for any live inspection.

A short note on rejection trains the model to avoid the same false positive.

Verification action
Anomaly
AI detected: misalignment
AI 69%

Needs verification

Inspect the highlighted photo, then choose: verify, correct, or reject.

Action needed
misalignment
moderate • score 3

on BEN CHPP Desliming Screen DS-2

thermal-v2.3 (demo)

DEMO: the feed-end exciter runs 67.5°C, about 20°C hotter than the discharge end. Uneven exciter temperatures on a linear-motion screen suggest a lubrication or mechanism-alignment problem. Check the oil level and the timing between exciters.

A short note on rejection trains the model to avoid the same false positive.

Verification action
Anomaly
AI detected: wear
AI 58%

Needs verification

Inspect the highlighted photo, then choose: verify, correct, or reject.

Action needed
wear
minor • score 2

on BEN CHPP Tailings Pump TP-1

thermal-v2.3 (demo)

DEMO: bearing housing 89.1°C but the frame was captured 4 minutes after restart, so it may be normal. Low-confidence call: confirm with a repeat scan at steady state before acting.

A short note on rejection trains the model to avoid the same false positive.

Verification action